Measurement Specialties Inc. NetScanner System (9016, 9021, & 9022) User’s Manual
2 - 6
Use of Static or Dynamic IP settings may be selected through the Set Operating Options ('w')
command. If you are unsure how your module is configured, check the Tx LED during module
power-up. If it begins to blink periodically after the module power-up, your instrument is
configured for the Dynamic IP assignment protocol. (Tx LED remains OFF in static IP
configuration.) If configured for Dynamic IP assignment, a dynamic server must be configured
on the network to return an IP address to the module. Without an IP address, the host will be
unable to open a TCP/IP or UDP/IP connection to the module.
2.3.5 Diagnostic Port Hookup
Each NetScanner
System module contains a Diagnostic Port that supports diagnostic and
operational functions. The Diagnostic Port has only a simple RS-232 asynchronous serial
interface. The connections are made via certain pins of its common circular connector. Cable
connection should be made according to Table 2.1.
NetScanner
System
Diagnostic Port
Connector
GND
Tx
Rx
Table 2.1
Diagnostic Port Wiring