Pressure Systems 9022 Manual de usuario Pagina 112

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 194
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 111
www.meas-
spec.com
Measurement Specialties Inc. NetScanner System (9016, 9021, & 9022) User’s Manual
1 - 79
which should be replaced as follows. The sequence ‘T’, ‘I’, and ‘U’ were piecemeal parts of the
(now obsolete) command ‘M,’ which was itself replaced by Read Scaled Analog Inputs (‘L’).
Also, there is the higher-resolution alternative Read High-Precision Data (r’) command. The
piecemeal pair of calibration commands ‘g’ and ‘W’ have always had a complete alternative, the
Calculate and Set Offsets (‘h’) command. Likewise, the other pair of calibration commands ‘X’
and ‘Y’ have always had a complete alternative, the Calculate and Set Gains (Z’) command.
Vista de pagina 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 193 194

Comentarios a estos manuales

Sin comentarios