Pressure Systems 9022 Manual de usuario Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 194
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
Pressure Systems, Inc. NetScanner™ System (9016, 9021, & 9022) User’s Manual
www.PressureSystems.com
3 - 77
RE-BOOT MODULE (UDP/IP Command ‘psireboot’)
Purpose: To unconditionally “reboot” a specified module.
Command “psireboot ethadr”
where ethadr is the Ethernet address
of the specified module in the
following special hex-digit format
‘xx-xx-xx-xx-xx-xx’
Response
none (module reboots)
Description: When a module receives this broadcast command, (by continuously monitoring port
7000) it responds by immediately restarting its firmware. The result is essentially the
same as a power-up restart, in that any TCP/IP connection is lost, and the module
returns to its normal startup state. The host must wait long enough for the re-boot
process to be completed before it can again request a connection to the module.
Example:
! Re-boot a specified module on the network.
“psireboot 00-E0-8D-00-00-01”
Response:
(None)